2nd floor slab rebar spacing. Once you have determined that the foundation of the house is strong enough to sustain a concrete floor, lay down wood sheeting. 2nd floor slab rebar spacing

 
 Once you have determined that the foundation of the house is strong enough to sustain a concrete floor, lay down wood sheeting2nd floor slab rebar spacing  Expert Help

Because of this, the Building Code places limitations on the size and spacing of rebar in gunite & shotcrete. Generally, a #4 (1/2″) diameter reinforcing bar with a minimum grade of 40 is used for standard residential slabs. The number ranges from 10-to. An older reinforced concrete design calculator that computes required steel area for T-beams and 1-way slabs can be found here. The practice in which steel decks are used is known as composite floor decks. 8 mm) when subjected to 50 pounds (23 kg) applied over 1 inch square (645 mm) of material and are greater than 1 / 8 inch (3. 5/16" 2" long bolts thru tight holes spaced 3" apart at the outer ends and then increasespacing by 1/2. Often, concrete contractors don’t have solid runs of rebar anyway. Understanding the Importance of 2nd Floor Slab Thickness for Building Safety and Stability in the Philippines The safety and stability of a building depend on various factors, and one of the most crucial is the thickness of the second-floor slab. spacing requirements and to repeat bar size and spacing as often as possible. Ordinarily, the rebar supplier details, fabricates, and delivers to the site, as required. The main reinforcement of the slab panel “A” is marked as (1). 87 d Spacing of bar = Design of Continuous Slab Suppose a slab is supported at the ends and also at intermediate points on beams, the maximum sagging and hogging moments to which the slab is subjected to due to uniformly distributed load, can be computed as follows: Let = intensity of dead load per square metre. The more layers of rebar you have, the harder it becomes to properly vibrate the concrete. • Edge beams act as L-beams, and interior. . 00 m 21 reinforced concrete slab 3 mm for every 3. The first step in getting reinforcement design for an elevated slab floor is defining design strip rules. Y. Rebar Spacing for Concrete Slab. Exposed rebar will rust, compromising the concrete's strength. A basic rule to follow when judging how deep a control joint should be is that it should be roughly 1/4 the depth of the concrete. (150 to 250 mm). Two-Way Concrete Floor Slab with Beams Design and Detailing Design the slab system shown in Figure 1 for an intermediate floor where the story height = 12 ft, column cross-sectional dimensions = 18 in. , 12, 24,. ( W) Width of the slab. If the slab in question is just for a patio or a similar purpose, #3 rebar with a diameter of 3/8-inch will do just fine. #construction #Philippines #staircase #stair #stairs #stairsPhilippines#steelbar #rebar #stairrebarRebar details for stairs and slab ThicknessAmerican Concrete Institute—there's not much available free from ACI, but if you want the best information on concrete and concrete parking lots, ACI has it. Column spacings are 48 feet center to center. longer than the length of the slab. In this video, I'm sharing you the process of concrete pouring and sizes/spacing of rebars for the beams and slab concrete for the 2nd floor of this project. Minimum. 15m and then Sand level is rammed. Setting a Max Bending Check value controls the rebar which the program chooses for the slab design. The building code requires a minimum of No. 3: Two-way slabs supported on four sides; Clause 6. For a 12 inch (30. Reading time: 4 minutes. our detail shows rebar from the top of footing to the second floor (extended above slab for as required for lap) and from 2nd to 3rd floor slab. To define design strip rules, click the Slab Design Rules button on the Data Entry toolbar. Horizontal rebar starting at 12 inches and at 18 inch intervals after to the top. Download : Download high-res image (140KB)Others say rebar in the middle is a waste. Typically, once the concrete in the foundation wall has set, install the floor system. LIFT MODELS. C. You’ll also need vertical rebar hooks protruding at least 6” into the footing and out at least. The support for reinforcing steel in floor slabs is shown in figure 7-24. Before placing the re-bar, correct spacing given in the detailing drawing were marked by using piece of choke on the slab formwork. The design and spacing of expan-sion and control joints is genera l l ysee table 3 for spacing. Rebar is recommended on concrete measuring 5 – 6 inches thick. bars at each corner 38mm clear 400 slab opening omit trimmer bars where typ. For residential footing use, spacing depends on the type of footing you have. The spacing of the rebar is also determined by the weight and size of the slab. In the Philippines, buildings face various environmental challenges such as strong typhoons, earthquakes, and floods. 9mm deformed rebar for walls instead of 10mm. To se-lect the appropriate steel area (As), use theFor example, if both slabs have rebar mats that are spaced at 18 inches and use No. Unfortunately, rebar can cause extensive damage to construction tools if you are performing coring or concrete cutting work. 3. 2. then use 1/2 PEX tubing and create about 5 floor heating circuits, bring all of them to a convenient access point in the shop. 125mm. The reinforced concrete floor slab is kept free of the perimeter walls. Rebar Spacing. The top of the wall will need "hooks" in the rebar in order to fasten the wall to the garage slab. #5 bars are 5/8”. In this article, we will examine the importance of reinforcing concrete with rebar and the proper steps. The architect's instructions on the plan are: “New conc slab with #3 transverse bars at 12” O. 5 bars; There shall be a minimum clearance between parallel reinforcement bars of 2 1/2 inches;. 1. These new concrete slabs do not account for second floor installations or installations in a ground floor with a basement beneath. 5" 3,000 PSI / 28 Day Aging. Draw also the typical beam detail showing the main. Generally, #4 rebar (1/2 inch in diameter) is the most common size used for slab on grade applications. The spacing of such shrinkage-temperature steel cannot exceed 18 in. Whether the frame is precast, cast-in-place, masonry, or structural steel it can be accompanied by a HollowCore floor slab system. A 6-mil (0. A residential post-tensioned concrete slab will typically be 8 inches thick and use 3000 psi concrete. MINIMUM VERTICAL REINFORCEMENT AND SPACING (INCHES) b, c: Soil classes and later soil load d (psf per foot below grade) GW, GP, SW and SP soils 30: GM, GC, SM, SM-SC and ML soils 45:Concrete Floor Slabs On Grade Course# ST-702 EZ-pdh. Use VERIA's free construction material quantity calculator to aide you in estimating for the materials and labor man-hours of all your construction projects. For this case, the lift should not be installed without. The suspended reinforced concrete slab is tied into the external capping beam. Grads Slab/ Slab on grade: The slab which is cast on the surface of the earth is called a Ground slab. , edge beam dimensions = 14 in. 42d. • Basement floor slabs with integral footings must provide for 5000 psi concrete in that portion of the slab acting as a footing. For multi sided slab, first draw the shape: 1: Hit Clear + Start and enter Side Length of first side to draw, then hit appropriate direction (Arrow) button to draw. I was thinking of the following: basement wall 8 inches thick 10 feet high backfilled up to 7 to 8 feet. 3. 7. , edge beam dimensions = 14 in. I was thinking of the following: basement wall 8 inches thick 10 feet high backfilled up to 7 to 8 feet. 34 and $7. 1 L from the center of the support at end support and 0. ACI 332, Section 10. . 1) provides the code basis. 3, No. for early-entry sawed joints. You should still use reinforcement material, but there are other options besides rebar. 3. Compressible floor-covering materials that compress more than 1 / 32 inch (0. Often it is necessary to cut holes in concrete floor slabs. SLAB MIN. In two-way construction, According to Clauses 8. For areas where heavy vehicles or equipment may be placed, our independent third-party engineers will specify rebar reinforcement for concrete slabs on grade. If the maximum diameter for slab thickness is 75 mm, so the diameter of reinforcing bars should be 8 mm. Methods used for finding slab thickness varies for different types of slabs. In inches the diameter of a #5 rebar is 5/8″ and that of a #4 rebar is 1/2″. 34 and $7. Expert Help. e. slab opening det. In this video i will show you about 2nd Floor Slab Rebar. Two layers of steel bar reinforcement are needed for secondary containment floors because tank loads induce both positive and negative bending moments in the floor. If consolidation of plastic soils is determined to be a potential problem a suspended slab may be the only effective solution, in which. or >) The minimum floor thickness shall be 6 inches. rebar strength is in tension, so by adding rebar to BOTTOM of foundation, it counter acts the load of compression. Our engineers wanted to make sure that big yellow boots fit between the rods so the workers did not stand on the rod and bend or. With some limitations, reinforcement for slabs can be sized using the Subgrade Drag Theory in order to increase the spacing of control or construction joints. 5% of the cross sectional area of a slab. dustrial floor slab. then use 1/2 PEX tubing and create about 5 floor heating circuits, bring all of them to a convenient access point in the shop. Why Does Concrete Require Rebar? Most concrete requires some type of reinforcement. Metallic and non-metallic pipes and conduits. reinforcing bars. On average are required, for 100 square feet with 5 inches thick slab, 19 strips of 3/8” rods (30 ft each one), are 570 ft. (I think someone touched on this) Your floor covers some span. b) Slab depth does not exceed 200 mm when the steel grade is 460. 74 equals 1824 lbs per sq feet. The formula is, Number of bars = (length ÷ spacing) + 1. However, this is the absolute minimum and applies only when there is no load on the concrete slab at all. Generally, rebar has an immense impact on concrete. Cutting length of main bar = Clear span of slab + (2 × Development Length) ( 2 × D e v e l o p m e n t L e n g t h) + Inclined Length - Bend Length. 24-foot joint spacing. Reduce evaporation over the slab by using a fog spray or slab cover. ACI 318-08. AI Homework Help. Floor slabs can range from a simple residential basement slab to a heavy-duty industrial floor. In t e r p r etations of the ACI 318 code re q u i r ements (Ref. Where, d is the diameter of the bar. standard rebar lenght is normally 12m or 6m each. A slab with this joint spacing may be reinforced with bars (ASTM A 615, A 616, A 617, or A 706) or WWF (ASTM A 185 or A 497). For these cases, the flat plate is economical for spans between 15 ft and 20 ft. HollowCore floor slab systems provide construction flexibility, fire separation, vibration isolation, and the structural support required to span almost any challenge that large or small multi-deck buildings require. Contraction joints (or control joints), when cracked, are really just straight shrinkage cracks. Concrete volume calculator plan view diagram. 15% for mild steel bars. Figure 1a: Joint Spacing in Meters. With this calculator, you’re trying to calculate the dimensions of your rebar grid (length and width). 1. CONTROL JOINT SPACING. 34 inch (8. You will be able to add radiant floor heat any time. (Imagine you are walking around the slab) Hit Undo Last to Undo last side. some different types of rebar affect not only the str ength but also the longevity and durability of concrete structures. 1 the spacing of links along the FULL HEIGHT shall not exceed 6 times diameter of smallest longitudinal bar or 150mm. )(100)/(6 in. In this video i will show you about 2nd Floor Slab Rebar. . That is, there are breaks in the rebar along the runs. c. Vertical rebar every 16 inches. on center, but this will depend on the structural design. The top of the wall will need "hooks" in the rebar in order to fasten the wall to the garage slab. 2. For example, a slab that is 6 inches thick might have rebar marked as size 6 or 3/4-inch. , interior beam dimensions = 14 in. Use 3/8 min repair frame in the footing. t + d Lsy. 1. At a maximum spacing of 120 inches (3048 mm). 00 m 21 reinforced concrete slab 3 mm for every 3. The openings are square in shape and range in size from 2 ft to 5 ft. If you want, you can cut out of a section of the steel for testing too. 59 per square foot. Besana. FIrst, find number of rods required for main reinforcement and distribution. Finally, you pour the concrete into the molds. The size of the rebar depends on the specific application, but typically #4, #5, #6, and #8 rebar are used. Glass fiber reinforced polymer. Steel shall be located within 2” of the top or the upper 1/3 of the slab. There should be a minimum of 3 inches of clear cover from the fi nished surface of the slab. Crack Control – when crack widths are not checked by calculations No Further Checked Required. This article presents steel quantity computation process for slabs, columns, and footings. 2. 1 m) and post-tensioned spans of 13’-28’ (3. For columns and beams, the minimum spacing should be 6 inches. Larger areas, lower loads, and higher seismic zones. 5h ≤ 450mm (in areas of concentrated loads 3h ≤ 400mm) Where h is the thickness of. In the case of the RCC slab, the maximum spacing between two secondary parallel wires should be 5D or 450 mm or whatever. Fo r decades ACI 318 has re q u i r ed high- Concrete slab-on-ground floors shall be designed and constructed in accordance with the provisions of ACI 332 and this section. Methods used for finding slab thickness varies for different types of slabs. This is one of the types of concrete slabs. For a flat slab, such as a driveway, consider placing the rebar in an 18 inch grid spacing, keeping the edge rebar at the same distance from each side. Often, concrete contractors don’t have solid runs of rebar anyway. The spacing of the rebar is also determined by the weight and size of the slab. vided in the slab under the net. For live loads of about 50 psf (2. Minimum thickness of concrete slab, beam, column, foundation and other structural members is selected to meet the design requirements as per standard codes. 2 mm) in thickness in the uncompressed state shall not extend beneath walls, partitions or columns, which are fastened to the floor. and 6000 btu/hr heat loss in the second. For beams, these distances are 300 mm, 180 mm and 150 mm for grades of main reinforcement of Fe 250, Fe 415 and Fe 500, respectively. Most residential slabs contain reinforcement of less than. A 4" slab should have joints 8-12 feet apart. 9. 53 Compute moments At support: ( - ) M1 = 3. To maintain strength and longevity, concrete slab rebar spacing must fit together like a jigsaw puzzle. There should be a minimum of 3 inches of clear cover from the fi nished surface of the slab. Concrete slab reinforcement design and code checks can be performed based on the following codes: ACI 318-19. 376 lbs/ft or 0. 2ND FLOOR CRACKING WIDTH. 9 Factored loads Factored dead load = 3. Sunitha K Nayar, gives the grouping of slabs-on-grade based on the design philosophies and a brief overview of the different design methods, the commonalities between design strategies in terms of the input parameters, assumed and estimated parameters, and the relevance of each. worked on the rebar behavior inspection of a sustainable RC slab. Generally, you do not need rebar for a 4-inch slab. Marine Plywood Requirement Area of each marine plywood = 2. Modeling floor diaphragms. slab along the shorter span, 3mm per meter span. Minimum clear cover to reinforcements in slab depends on the. If the floor is. Two-Way Concrete Floor Slab with Beams Design and Detailing Design the slab system shown in Figure 1 for an intermediate floor where the story height = 12 ft, column cross-sectional dimensions = 18 in. We would like to show you a description here but the site won’t allow us. Minimum reinforcement is 0. Rebar Development Length Calculator is a web application that supports the design of post-installed rebar in concrete applications by calculating the necessary tension and compression development lengths required in accordance with ACI 318-19 / ACI 318-14. It is possible to pour a concrete garage floor without installing rebar for reinforcement. Tying is required at every second or third intersection, depending upon the size and spacing of bars, but with not less than three ties to any one bar, and, in any case, not more. Here: Bar Tying Requirements. The current British Standard or guideline for tying reinforcement can be found in the document BS 7973-2:2001 (Spacers and chairs for steel reinforcement and their specification — Part 2: Fixing and application of spacers and chairs and tying of reinforcement). 84 m; grid. I am confused about the grid. In two-way construction,According to Clauses 8. 9 cm)-round bar 05 = part of second floor plan designated by the number 5. UB 610 x 179_BP_Pinned. Workmanship and jobsite conditions. Concrete slab-on-ground floors shall be designed and constructed in accordance with the provisions of this section or ACI 332. Rebar should be placed evenly throughout the project. It’s not necessarily the placement of the rebar in the slab but the amount of rebar/rebar spacing and the depth of the slab. Important Points. 10mm, 12mm, 16mm, 20mm. Select the unit of dimension like meter, feet inch, etc. The minimum column size should not be less than 9 "x9". There are three different sizes of rebar typically used for home construction projects. 2): where f s is the calculated stress in the flexural reinforcement closest to the tension face of the section. 2 and 9. Much of your need for reinforcement will be dictated by how well your site was prepared. Annex. 5 m) with mini-mum slab thicknesses of 6 to 10 in. Unit 571 New Smyrna Beach, FL 32128 386-882-EZCE(3923). The result is a lightly reinforced slab designed to offset the effects of temperature and shrinkage of the concrete. It also provides worked examples,. It is not hurting anything by putting it in a floor slab, but unless it is in the bottom third of the slab, it is providing zero strength, just keeping the pieces together if it cracks. 75 to 3. How far apart should rebar be spaced? approximately 12 inches Place rebar in a grid pattern with a spacing between bars of approximately 12 inches. (as in example diagram) First, enter the concrete slab sizes: length = 6 m, width = 4 m. 2 cm) from the bottom of the concrete, and side clearances range from 2 to 4. 50 m span joist, beams, & girder soffit under 3. The mesh reinforcement in the slab is placed in the top with 1" covers. SLAB REINFORCEMENT SIZE REINFORCEMENT SPACING ANCHOR ANCHOR Cutting that rebar ain’t going to do shit, despite all the “engineers” comments to the contrary. 8 of the Florida Building Code,. Slab may be supported on walls or beams or columns. 10) Deflection and end-slip behavior. Build the wall full height, place concrete continuously in 4-foot lifts, and consolidate each lift. Corner angle. 113. , or 5 h, where h is the slab thickness. For slabs of septic tanks, you usually use #3 and #4 bars. But as the depth grows, so does the need for reinforcing the structure. Horizontal rebar starting at 12 inches and at 18 inch intervals after to the top. 6 inches. 3. Clear cover of the slab = 25-mm. The slab is constructed on well compacted granular fill, crushed stone or marl. It follows that the design yield strength of reinforcing steel that may be used in a slab designed in accordance with AS 3600-2000 is 400, 450 or 500 MPa. R403. Finite elements 1st example 2nd example 3rd example. 1: Calculate The Main bars. 5 round bars, respectively, while. 5 kPa), column spacing typically ranges from 15 to 25 ft (4. girder sides & slab on grade - 1 reinforced concrete beams 6 mm for every 4. Larger diameter bar will allow a wider spacing of the bar, our designs went from 3/8 on 12 inches to 1/2 on 18 inch when we started to build pesticide storage facility's. 00 m to 6. 2: Repeat and continue to draw complete (closed) shape. Second, in cases where a T-beam is oriented so that it is parallel to the main slab reinforcement (e. 18 bar 11/2″. In the case of the RCC slab, the maximum spacing between two secondary parallel wires should be 5D or 450 mm or whatever. Enjoy the Rebar Calculator for Slab. Then use USDA NRCS Standard Drawing ES-46 to select ( ) There's no generally-accepted rule of thumb as to how to space rebar in a concrete slab. Then insert 6-foot-long vertical rebars in the cores, properly positioning them in the rebar chairs. The concrete floor will be reinforced according to WAC 246-359-430. 00 m to 6. 1 of the 2021 International Building Code (IBC) specifies that the thickness of concrete floor slabs supported directly on the ground shall not be less than 3 1/2″. Reinforcing bars that are spaced too far apart could result in relatively large flexural crack widths. ACI 360, "Design of Slabs-on-Grade", refers to this as a Type B slab. last quarter of 2014, the prices i got for the rebars (12m lenght) are: 9mm deformed rebar - P110 10mm - P138 12mm - P205 16mm - P385. 5% reinforcement (reproduced here as Table 1). If your two slabs have different spacing for their rebar mats, measure and mark so your dowels fall in the middle of the spacing of the second slab. Table 7-6. It depends on what the 4-inch slab is being used for, as well as the location and soil type where it will be poured. Carbon steel. Advertise Here. What Size Rebar for Concrete Slab? This usually depends on the intended workload. The Rebar Calculator is now available in Spanish. I did a finite element model and the remaining reinforcement seems enough after the slab is cut. A concrete slab costs between $4. Second, the slab is allowed to elongate freely in the whole length of DFR, thus reducing its strain to the value. If the weight of each steel beam is 62 lb/ft, determine the dead load in lb/ft supported by any interior beam. ˘ ˘ˇ Spacing (Rebar) A-7 4-1/2” 4000 psi with 28 day aging #6 rebar 12 in. 1 of ACI 318-111 identifies a two-way slab as a slab system designed for flexure in more than one direction. 14 and No. 0 pounds per cubic yard (0. For M15 concrete, lever arm = 0. of the most advantageous location for a floor opening depends on the type of two-way slab you’re designing or evaluating. I am pouring a slab for radiant heat next week and I have been given a variety of advice on whether or not to use rebar. Technical Details of Steel Decking in Composite Floor Slabs. 1 Flexural Cracking in Reinforced-Concrete SlabsFor mid-depth rebar, the program will use the bottom bar size and spacing options. 15 feet x 12 inches per foot = 180 inches. unless otherwise noted in plans or specifications, camber all r. Rebar comes in several types: Steel mesh, made up of steel wires that provide support to the concrete. ACI 318-14. These beams are not fixed together with a slab as are superstructure beams; consequently concrete has to be poured down the beam’s narrow top opening and reach the bottom of the beam. Number of Distribution Bars = Lx / spacing + 1 = 3000/150 + 1 = 21 nos. In either case, blocks should be used under the reinforcement to keep centered within the concrete. In some cases, concrete needs reinforcement with steel mesh. The second marker expresses the bar size and is demonstrated by a number. And the rebar details of (1) is 10mmØ @ 8″ c/c. Floor Under Solids or Semi- solids and Single Axle load (15,000 lbs. south d c rebar i 306" i #7,7/8" dia ---j r--rebar j. Detail B: “Wrap and Snap Tie” (diagram upper right) is normally used when tying vertical wall reinforcement to hold the bars securely into. g. Floor slab of bottom-most SS or NS and floor slab of NS located above an SS: (i) Slab reinforcements at both external face and internal face shall be H13-. Concrete doesn't dry out; it undergoes a chemical curing process that creates a dry, solid mass. 00 m 7. Dowel bars transmit the weight from one slab to its neighboring slab. spacing, and other details. 1. 87 d Spacing of bar = Design of Continuous Slab Suppose a slab is supported at the ends and also at intermediate points on beams, the maximum sagging and hogging moments to which the slab is subjected to due to uniformly distributed load, can be computed as follows: Let = intensity of dead load per square metre. For a 400 square foot slab, the man hours required to finish a two-car concrete garage slab is about 13 hours. We’ll run through these ties now: Saddle ties:As per clause 11. For the slab's longer dimension, you'll need 360 inches divided by 14, which gives you 25 plus a bit left over. Figure 1 shows an example of a floor plan with a composite slab including supple - mental reinforcing bars. REBAR SPACING: GP‐7 SERIES MODELS: 4‐1/ 4" 3000 PSI / 28 Day Aging #6 Rebar: 12 in: XPR‐9 SERIES MODELS: 4‐1/ 4" 3000 PSI / 28 Day Aging #6 Rebar:. 30% carbon cont ent and only. However, if the concrete slab is meant to be the footing of a small structure, #4 rebar with a diameter of 1/2-inch should be used. Figure 2 illustrates the typical locations of the top and bottom bars within the composite slab cross-section. ACI 318-11. Place the second bar parallel to the first bar and 1 inch beyond (see Figure 2). (a) A flat plate which is a two-way slab supported on a column grid without the use of beams. For general purpose concrete slabs with 2,500 pounds compression strength, like patios, use a 1:2:4 concrete mix ratio. E. 1. Shrinkage cracks are probably the most common type of cracks in concrete. , interior beam dimensions = 14 in. ACI 330R-08, Guide for the Design and Construction of Concrete Parking Lots is. Rebar is tied together, using wire, to hold it in place. Properly compacted sub-grades can reduce needs for reinforcement – as well. I have some question regarding the placement of the expansion joints. The diameter of bar generally used in slabs are: 6 mm, 8 mm, 10 mm, 12mm and 16mm. Number of Distribution Bars = Lx / spacing + 1 = 3000/150 + 1 = 21 nos. I have 10 in. This new slab design does not account for second floor installations or installations in a ground floor with a basement beneath. Prepare and Place Reinforcement for Slab. 8 mm) when subjected to 50 pounds (23 kg) applied over 1 inch square (645 mm) of material and are greater than 1/ 8 inch (3 mm) in thickness in the uncompressed state shall not extend beneath walls, partitions or columns, which are fastened to the floor. S. Compressible floor-covering materials that compress more than 1/ 32 inch (0. 15. Figure 5. Step-4: Rebar Calculation Process Of The Slab Panel-A 4. com) 3. 36 Live load Canopy = 1. 3%. The movements of these structural elements are likely different than those of a slab-on-grade due toWhen operated by our highly trained Project Managers, GPR’s typical accuracy is +/- ¼” to the center of the object in concrete we locate: conduit, post tension cables, and rebar. 21 m 2. The floor has been designed with two mats of steel, 7 1/2" total concrete thickness and 50 ksi steel beams with a single row of shear studs on the beams. Fabrication of rebars consists of cutting to length and required bending. Concrete blocks made of sand-cement mortar can be used in place of the slab bolster. 2 Storey Building: For increased load-bearing capacity, a mix of 12mm and 16mm rebars could be appropriate. or slab change soffit typical detail for beam 400 dowel 250 300 (typ. Detail B: “Wrap and Snap Tie” (diagram upper right) is normally used when tying vertical wall reinforcement to hold the bars securely into.